Re: Make a fake RAID 1 for ESXI
I don't really understand how to use VSA. But from some reading it seems like I might be able to create the effect, though not with the exact same performance? Not sure if this works, but could deploy...
View ArticleRe: vSGA NVIDIATesla M2070-Q not working with vsphere 5.1
I have a ticket open with VMware for the same exact issue. They have confirmed that this is an issue with AMD procs and the NVidia VIB. I also confirmed it works fine on my DL380 (intel). So if you...
View ArticleRe: vSGA NVIDIATesla M2070-Q not working with vsphere 5.1
I have a ticket open with VMware for the same exact issue. They have confirmed that this is an issue with AMD procs and the NVidia VIB. I also confirmed it works fine on my DL380 (intel). So if you...
View ArticleRe: vSGA NVIDIATesla M2070-Q not working with vsphere 5.1
I have a ticket open with VMware for the same exact issue. They have confirmed that this is an issue with AMD procs and the NVidia VIB. I also confirmed it works fine on my DL380 (intel). So if you...
View ArticleRe: NVidia GPU not working for sVGA
I have a ticket open with VMware for the same exact issue. They have confirmed that this is an issue with AMD procs and the NVidia VIB. I also confirmed it works fine on my DL380 (intel). So if you...
View ArticleRe: SSO can't survive a simple reboot?
Don't worry, I didn't take this personally I'm just interested in what's causing the issue and the resolution, which I hope we will find.In the years I've been woring with Windows systems, I saw issues...
View ArticleRe: Maintenance Mode Required to Scan?
Yes, you can scan the hosts while they have running VMs. Maintenance mode is not required for this.
View ArticleRe: Allocated space, used and free space for all VM's in a data center
Thanks a lot. It ran just fine.
View ArticleRe: I need a script to log into guest OS desktop, similar to option in guest...
What is the error message you are getting back ?And do you run the script where you call the Invoke-VMScript from a 32-bit or a 64-bit PowerCLI session ?
View ArticleRe: orphaned vmdk files script
how about if we want to only report out of inventory vms on particular clusters only?
View ArticleRe: ESXi 5.1 management network no connectivity with two nics connected
The IBM BladeCenter H chassis has two BNT Layer 2/3 Modules. The HS22 has two gigabit network adapters (Broadcom 5709S). The way the chassis works is one adapter gets mapped to BNT module in bay 1 and...
View ArticleRe: Initiate Orchestrator workflow via REST/Post with JSON body
Burke - status code 415 indicates mismatch in the media type, which is expected because there is no Content-Type header KeyboardSlappingMonkey - I think the request body should be something like the...
View ArticleRe: Welcome!
Hey Everyone, Work in DC and live in Waldorf, MD. How is everyone? Thanks!
View ArticleRe: SSO can't survive a simple reboot?
I had one of our guys who's never logged on to the vcenter box, logon with his domain creds just fine. I'll go through the domain hoops after I reboot it one more time. post reboot I see event id...
View ArticleRe: Initiate Orchestrator workflow via REST/Post with JSON body
GOT IT!! Okay, two things I had error with:1) In that last couple attempts, I had the body wrong - I had specified input-parameters instead of "parameters"2) json value format After updating those two...
View ArticleRe: VAAI - Extended Statistics for NAS
Thanks Mark, I can't see them under ESXtop at this stage but may be looking in wrong spot. If I go ESXtop and specify U for disk device I see my NFS volumes but not the stats you mention. Toggling the...
View ArticleRe: Initiate Orchestrator workflow via REST/Post with JSON body
Duh, I should have thought to look at the json format of an existing workflow execution - it clearly shows the proper format of the value field. I should have caught that as that was the technique I...
View ArticleRe: ESXi 5.1 management network no connectivity with two nics connected
Since you mentions LACP, how did you configure the port group/vSwitch policy. With separate switches (i.e. not stacked), you should be using the default policy (Port based) with the physical switch...
View Article